<LOGO>
FM Transmitter Measurement Report
Created: 2025-05-05 04-05-47
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 58 dBuV SANDELS
Pilot RDS Phase Difference
4.7 kHz 5.4 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 71 kHz 14724 13,1282
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,2 dBr 5,23 dBr 5,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 71 kHz MIN: 13 kHz % above 76 kHz: 13,1282 Acquired: 2025/05/05 4.04.43 Total samples: 14724 Equivalent time: 0:12:16 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 5,9 dBr MIN: 4,2 dBr AVE: 5,23 dBr % above 12,2 dBr: 0,0 Last value: 4,9 dBr (2025/05/05 4.04.42) 03.50 03.52 03.54 03.56 03.58 04.00 04.02 04.04 0 2 4 6 Pm [dBr]